A technique is described for selecting the RPA clasp (rest, proximal plate, Aker’s clasp) and making a Kennedy class I removable partial denture in the mandibular arch using the computer-aided design and computer-aided manufacturin technology. A benchtop scanner (3Shape®, Copenhagen, Denmark) captures the plaster cast image, and software (Exocad DentalCAD®, Darmstadt, Germany) processes it. All the initial planning was carried out; however, because of the digital flow analysis to obtain the printed cast, the design of the metallic frame was changed due to the need to modify the retention clip on the abutment teeth. The other clinical steps for the installation of the removable partial denture were followed in the laboratory to obtain satisfactory aesthetic and functional results. With this technique using the digital medium, the optimization of the workflow in dental prosthetic rehabilitation, easier work planning involving the clinical team and the dental technician, and the return of the masticatory function and aesthetics to the patient were observed.

Palavras-chave


Computer-Aided Design; Technology Dental; Dental Prosthesis Design.

Texto completo:

19

Referências


Kapos T, Evans C. CAD/CAM technology for implant abutments, crowns, and superstructures. Int J Oral Maxillofac Implants. 2014, 29S:117-136. doi: 10.11607/jomi.2014suppl.g2.3.

Chochlidakis KM, Papaspyridakos P, Geminiani A, Chen CJ, Feng IJ, Ercoli C. Digital versus conventional impressions for fixed prosthodontics: A systematic review and meta-analysis. J Prosthet Dent. 2016 Aug;116(2):184-190.e12. doi: 10.1016/j.prosdent.2015.12.017

Carneiro Pereira AL, Bezerra de Medeiros AK, de Sousa Santos K, Oliveira de Almeida É, Seabra Barbosa GA, da Fonte Porto Carreiro A. Accuracy of CAD-CAM systems for removable partial denture framework fabrication: A systematic review. J Prosthet Dent. 2021 Feb;125(2):241-248. doi: 10.1016/j.prosdent.2020.01.003

Fueki K. Digital removable dentures: A challenge in a super-aged society. J Prosthodont Res. 2020;64:vi.

Tregerman I, Renne W, Kelly A, Wilson D. Evaluation of removable partial denture frameworks fabricated using 3 different techniques. J Prosthet Dent. 2019;122(4):390-395. doi: 10.1016/j.prosdent.2018.10.013

Campbell SD, Cooper L, Craddock H, et al. Removable partial dentures: The clinical need for innovation. J Prosthet Dent. 2017;118(3):273-280. doi: 10.1016/j.prosdent.2017.01.008

Ahmed N, Abbasi MS, Haider S, Ahmed N, Habib SR, Altamash S, et al. Fit Accuracy of Removable Partial Denture Frameworks Fabricated with CAD/CAM, Rapid Prototyping, and Conventional Techniques: A Systematic Review. Biomed Res Int. 2021 Sep 6;2021:3194433. doi: 10.1155/2021/3194433

Almufleh B, Emami E, Alageel O, de Melo F, Seng F, Caron E, et al. Patient satisfaction with laser-sintered partial removable dentures: A crossover pilot clinical trial. J Prosthet Dent 2018;119:560-7. doi: 10.1016/j.prosdent.2017.04.021.

Yang Y, Zhang H, Chai Z, Chen J, Zhang S. Multiple logistic regression analysis of risk factors associated with denture plaque and staining in Chinese removable denture wearers over 40 years old in Xi’an - a cross-sectional study. PLoS One 2014;9:e87749. doi: 10.1371/journal.pone.0087749

Eliason CM. RPA clasp design for distal-extension removable partial dentures. J Prosthet Dent. 1983;49(1):25-27.

Hwang HJ, Lee SJ, Park EJ, Yoon HI. Assessment of the trueness and tissue surface adaptation of CAD-CAM maxillary denture bases manufactured using digital light processing. J Prosthet Dent. 2019;121:110–7. Doi: 10.1016/j.prosdent.2018.02.018

Kalberer N, Mehl A, Schimmel M, Müller F, Srinivasan M. CAD-CAM milled versus rapidly prototyped (3D-printed) complete dentures: an in vitro evaluation of trueness. J Prosthet Dent. 2019;121:637–43. doi: 10.1016/j.prosdent.2018.09.001

Steinmassl O, Dumfahrt H, Grunert I, Steinmassl PA. CAD/CAM produces dentures with improved fit. Clin Oral Investig. 2018;22:2829–35. doi: 10.1007/s00784-018-2369-2

Yoon HI, Hwang HJ, Ohkubo C, Han JS, Park EJ. Evaluation of the trueness and tissue surface adaptation of CAD-CAM mandibular denture bases manufactured using digital light processing. J Prosthet Dent. 2018;120:919–26. doi: 10.1016/j.prosdent.2018.01.027

Takaichi A, Fueki K, Murakami N, Ueno T, Inamochi Y, Wada J, Arai Y, Wakabayashi N. A systematic review of digital removable partial dentures. Part II: CAD/CAM framework, artificial teeth, and denture base. J Prosthodont Res. 2022 Jan 11;66(1):53-67. doi: 10.2186/jpr.JPR_D_20_00117

Ozawa D, Suzuki Y, Kawamura N, Ohkubo C. Fabrication of crown restoration retrofitting to existing clasps using CAD/CAM: fitness accuracy and retentive force. J Prosthodont Res. 2015;59(2):136-143. doi: 10.1016/j.jpor.2015.01.002

Su FY, Tsai JC, Morton D, Lin WS. Use of an open-source CAD software program and additive manufacturing technology to design and fabricate a definitive cast for retrofitting a crown to an existing removable partial denture. J Prosthet Dent. 2019;122(4):351-354. doi: 10.1016/j.prosdent.2019.02.017

Lee H, Kwon KR. A CAD-CAM device for preparing guide planes for removable partial dentures: A dental technique. The Journal of prosthetic dentistry. 2019; 122(1), 10–13.doi: 10.1016/j.prosdent.2018.06.011

Rissin L, House JE, Conway C, Loftus ER, Chauncey HH. Effect of age and removable partial dentures on gingivitis and periodontal disease. J Prosthet Dent. 1979 Aug;42(2):217-23.


Apontamentos

  • Não há apontamentos.


visitas

Indexadores: